Home > Care & Maintenance
Care & Maintenance Guide

Wipe Faucet Bodies & Handles

Daily Faucets pH-neutral cleaner
  • Spray a microfiber cloth (not the fixture) with pH-neutral cleaner.
  • Wipe body, spout, and handle/trim; buff dry to avoid spotting.
  • For brass/colored PVD, avoid abrasives and bleach.
~2–3 min / station

Clean sensor lenses (touchless)

Daily Electronics Distilled water or lens wipe
  • Use a soft lens cloth; lightly moisten with distilled water.
  • Wipe lens in one direction; dry with a fresh cloth.
  • Do not spray cleaner directly at sensors or seams.
~1 min / unit

Descale aerators (light)

Weekly Faucets 1:1 water–white vinegar
  • Unscrew aerator; soak in warm 1:1 vinegar for 10–15 min.
  • Brush gently; rinse thoroughly; reinstall with gasket.
  • For PVD/brass, protect finish; rinse any splashes immediately.
~8–10 min / faucet (soak time)

Auto-flush check & porcelain wipe

Weekly Urinals Non-acidic porcelain cleaner
  • Trigger test flush; confirm duration/coverage.
  • Wipe porcelain with non-acidic cleaner; rinse & dry.
  • Inspect sensor alignment, battery indicator, and seals.
~3–5 min / unit

Smart shower control clean & test

Monthly Showers No solvents / no ammonia
  • Power safe mode if available; wipe control dial & faceplate.
  • Run temperature calibration test; verify presets and flow.
  • Check hose & gasket wear; replace if flattened or cracked.
~10–12 min / shower

Porcelain/stone sink deep clean

Monthly Sinks Non-abrasive cream cleanser
  • Rinse sink; apply cream cleanser with soft sponge.
  • Work in circles; rinse thoroughly; dry to prevent mineral spots.
  • For stone, use stone-safe pH-neutral cleaner only.
~6–8 min / sink

Replace batteries / inspect wiring

Quarterly Faucets Use OEM battery type
  • Power off water as needed; replace batteries with OEM spec.
  • Check connectors for corrosion; apply dielectric grease if recommended.
  • Run activation tests; log service date & readings.
~5–7 min / unit

Descale showerheads & trim

Quarterly Showers Citrus descaler, soft brush
  • Soak removable parts; for fixed heads, bag with descaler 20–30 min.
  • Brush nozzles gently; rinse; polish with microfiber.
  • Avoid acid on marble/stone—mask surfaces before work.
~15–20 min / shower

Full fixture audit & seal replacement

Annually Restrooms Shutoff & PPE as required
  • Inspect supply lines, seals, traps; replace worn gaskets/O-rings.
  • Update asset tags; record model/serial & maintenance history.
  • Refresh finish protection with manufacturer-approved wax/sealants.
Varies by site

Mirror & splash zone care

Weekly Sinks Streak-free glass cleaner
  • Spray cloth (not mirror) to prevent edge creep; wipe top-to-bottom.
  • Dry splash zones to prevent mineral staining.
~2–3 min / bay

Trap & cartridge maintenance

Monthly Urinals Follow OEM procedure
  • Replace waterless cartridges / refresh seals as specified.
  • Flush & test for odors; inspect for hairline cracks.
~6–10 min / unit

Do: Use pH-neutral cleaners, soft microfiber, rinse & dry. Don't: Use abrasives, steel wool, chlorine bleach, ammonia on brass/PVD, or spray directly into sensors.

Sensor faucet won't activate

Quick Fix Electronics
  • Clean lens; verify power (battery/adapter) and polarity.
  • Check shutoff valves; re-seat connectors; reset per manual.
  • Ambient light or reflective basins can confuse IR—adjust angle/range.

Weak water flow

Quick Fix Faucets/Showers
  • Clean aerator/showerhead; check supply stops and filters.
  • Descale with vinegar; verify pressure regulator settings.

Finish spotting or tarnish

Care Tip Chrome/Brass/PVD
  • Rinse hard-water residue promptly; dry after cleaning.
  • Use non-abrasive polish approved by the manufacturer; avoid ammonia/bleach.

Urinal auto-flush too frequent

Tuning Urinals
  • Reduce sensitivity / shorten detection zone; eliminate reflective triggers.
  • Ensure proper mounting height and correct lens orientation.

Recommended Supplies

  • pH-neutral multi-surface cleaner (spray bottle)
  • Microfiber cloths (color-coded for fixtures, glass, porcelain)
  • White vinegar / citric acid descaler (finish-safe use)
  • Non-abrasive cream cleanser (porcelain/ceramic)
  • Soft nylon detailing brushes & old toothbrush for aerators
  • OEM batteries (for sensors), dielectric grease (if specified)
  • Silicone-safe lubricant for O-rings/gaskets (per OEM)
  • PPE: gloves, eye protection; masking for stone/marble near acids
  • Maintenance log (date, unit, work done, technician initials)

In short, FontanaShowers Care & Maintenance equips users with clear, actionable steps to preserve both performance and aesthetics of their fixtures. From daily wiping of faucet surfaces and sensor lenses to monthly deep-cleaning routines and annual audits, the protocol emphasizes pH-neutral cleaners, microfiber cloths, and finish-safe methods. It warns against harsh chemicals, abrasives, and direct sprays into sensors, and outlines quick fixes for common issues like weak flow or sensor malfunctions. Above all, consistency and proper recordkeeping (via a maintenance log) ensure that fixtures continue to operate flawlessly, extend their lifespan, and retain their intended look.