Automatic Sensor Faucet Designed for hygienic operation with infrared sensing, controlled discharge, and automatic shut-off performance. Reduces the transfer of germs by preventing cross-contamination and re-contamination of germs and bacteria by not touching the faucets or handles. Cut down on water usage by minimizing waste of water by eliminating unnecessary or unattended water flow.
Durable Vandal-Resistant Brass Body; Ideal for commercial high use applications. Intelligent with its micro-computer controlling its action, the faucet will self-adjust its best detection zone as per the color and shape of the lavatory. Flashing light indicator; a diagnostic indicator for power up, low battery, and solenoid function.
Convenient to maintain; with a built-in strainer to prevent sundries from entering the solenoid valve and the strainer is easy to clean. The faucet can be mounted to any sink surface. Battery life 8,000 cycles per month and with enough water pressure is approx 2 years service life of the batteries.
Sensor Activated Touchless Faucet Special Features:
|
Sensor faucet complete motion detection operation.
Commercial use.
Sensitive Sensor with Infrared AI Smart-Chip
Factory set to 30-second Auto Shutoff (can be adjusted).
Water Pressure: 0.1 - 7.0 KGS/cm , 10 - 125 psi
Solid Brass Construction, ORB Finish
Easy to Install - Instructions Included
Water resistant solenoid enclosure
Advanced energy saving design for long lasting battery life
Comes complete with Hoses & Accessories
Power Supply: AC110V And DC6V (batteries not included)
AC/DC power option.
Can be installed easily in new or upgraded retrofit commercial bathrooms.
Comes with 1 year of manufacturing warranty
The flow rate is 2.5 GPM
|
|
Fontana Verona Cold & Hot Touchless Bathroom Faucet FAQ
16–32 cm Adjustable Sensing, 2.5 GPM Flow;
Hot/Cold Regulation & IP56 Sensor Control
The Fontana Verona FS15065 combines hot/cold touchless operation,
solid-brass construction, adjustable infrared sensing, and
dual AC/DC commercial power.
What makes the Verona's self-adjusting sensor useful around different sink materials?
The micro-computer adapts the detection field to the color and
geometry of the installed lavatory. Final commissioning should
occur after the basin, countertop, mirror, and lighting are in
place, then the 16–32 cm sensing range can be refined to avoid
nuisance activation from reflective surfaces.
Which checks keep the 2.5 GPM hot-and-cold delivery stable?
Flush both supply branches before final connection, verify the
hot/cold regulator under normal dynamic pressure, and confirm
approximately 2.5 GPM discharge without irregular flow or leakage.
Stable inlet pressure and clean G1/2-inch plumbing help protect
the solenoid and mixing components during repeated commercial use.
Why does the built-in strainer matter to long-term valve reliability?
The strainer prevents pipe debris and suspended particles from
reaching the automatic valve. Inspect and clean it whenever flow
declines or valve response changes. Keeping the strainer serviceable
helps preserve the motor valve, which is rated for up to approximately
500,000 operating cycles.
When should the IP56 controls and 60-second cutoff be tested?
Verify the protected control enclosure, AC/DC power paths, sensor
response, and automatic cutoff during final commissioning. Hold a
target continuously within the sensing field and confirm that extended
flow is interrupted after approximately 60 seconds, then verify normal
operation resumes on the next valid activation.