Home > Fontana Brio PrimeSense™ Line | Faucet Installation Height & Basin Clearance

Fontana Touchless Faucets™ | Architectural and Engineering Resource

Fontana Brio PrimeSense™ Line FS-1095GMG Gun Metal Gray Touchless Bathroom Faucet: Faucet Installation Height & Basin Clearance

This faucet installation-height and basin-clearance drawing resource is intended to support architects, plumbing engineers, interior designers, countertop fabricators, millwork contractors, installers and facility managers coordinating the Fontana Brio PrimeSense™ Line FS-1095GMG touchless bathroom faucet with a commercial lavatory basin. The drawing establishes the relationship between the finished countertop, faucet mounting plane, spout outlet, basin rim, basin interior, water-stream landing area, infrared sensor zone, backsplash and under-counter components so fixture placement can be coordinated before countertop fabrication and final installation.

Fontana Brio PrimeSense™ Line FS-1095GMG Touchless Bathroom Faucet

The Fontana FS-1095GMG is a single-hole, deck-mounted automatic faucet designed for touch-free commercial handwashing applications. Correct installation height and basin coordination are important because the faucet outlet, infrared sensing field and water-stream trajectory must work together with the selected lavatory geometry to provide reliable activation, comfortable hand clearance and controlled splash performance.

  • Model: FS-1095GMG
  • Product type: Touchless bathroom faucet
  • Installation: Deck mounted
  • Mounting: Single hole
  • Finish: Gun Metal Gray
  • Operation: Infrared sensor activation
  • Sensor range: 16–32 cm adjustable
  • Water connection: G1/2"
  • Flow rate: 1.2 GPM [4.54 L/min] at 60 PSI
  • Temperature mixing: Below-deck mixing arrangement
  • Automatic timeout: 30 seconds factory default
  • Application: Commercial and institutional washrooms

Required Faucet Installation Height & Basin Clearance Drawing Package

The installation-height drawing should use the finished countertop as the primary vertical reference plane and should clearly show the faucet body, spout outlet, basin rim, basin interior, water-stream landing point, sensor-detection field and backsplash. Vertical and horizontal clearances should be coordinated with the actual basin selected for the project rather than a generic lavatory profile. Final construction dimensions should be verified against the approved FontanaShowers product submittal and actual fixture samples where critical.

Complete Installation Height & Basin Clearance Elevation

Shows the complete relationship between the FS-1095GMG faucet, finished countertop, basin rim, bowl interior and water-stream landing area. The elevation should establish all relevant vertical heights and horizontal clearances needed for coordinated fixture installation.

Finished Countertop Reference Plane

Use the top of the finished countertop as the primary elevation datum for faucet mounting and height dimensions. Countertop substrate, build-up and support layers should not be substituted for the finished surface reference.

Faucet Overall Height

Show the vertical dimension from the finished countertop to the highest point of the faucet body. This dimension assists architectural coordination with mirrors, shelves, backsplash features and adjacent washroom accessories.

Spout Outlet Height

Show the vertical distance from the finished countertop to the water outlet. The outlet height should be coordinated with the basin rim and bowl depth to provide adequate handwashing clearance while limiting splash.

Spout Projection

Identify the horizontal projection from the faucet mounting centerline to the center of the water outlet. The projection should place the water stream within the basin’s effective capture area.

Basin Rim Elevation

Show the basin rim or countertop-basin transition relative to the faucet outlet. Vessel, drop-in, integrated and undermount basins may produce significantly different clearance conditions.

Outlet-to-Basin Rim Clearance

Provide sufficient vertical and horizontal clearance between the faucet outlet and basin rim so users can comfortably place their hands within the sensing and washing zone without contacting the fixture or basin.

Spout-to-Basin Edge Clearance

Show the horizontal relationship between the outlet and nearest basin edge. The clearance should prevent the water stream from striking the rim while maintaining an effective hand-detection zone in front of the sensor.

Basin Interior Depth

Identify the usable bowl depth below the rim or countertop plane. Basin depth has a direct influence on splash performance and should be evaluated together with faucet flow, outlet height and stream trajectory.

Water-Stream Landing Point

Show the intended location where the faucet stream contacts the basin. The stream should land within the central usable bowl area rather than directly on the drain, steep sidewall or front rim.

Water-Stream Trajectory

Illustrate the expected path from the faucet outlet into the basin. This provides a useful coordination reference when selecting basin depth, drain location and mounting centerline.

Infrared Sensor Zone

Show the adjustable 16–32 cm detection field in relation to the faucet outlet and basin. The sensor should recognize normal hand movement without continuously detecting the basin itself.

Handwashing Activation Zone

Identify the practical hand position where the user enters the infrared sensing field and receives water flow. The activation zone should overlap naturally with the basin’s comfortable handwashing area.

Sensor-to-Basin Clearance

Maintain sufficient separation between the sensor field and reflective basin surfaces. Excessively close or highly reflective surfaces may require sensor-range adjustment during commissioning.

Backsplash Clearance

Show the horizontal distance from the rear of the faucet to the backsplash. Sufficient clearance should be provided for installation, cleaning and maintenance without the faucet body contacting the wall finish.

Mirror Clearance

Where mirrors extend close to the countertop, confirm that the faucet height and projecting geometry do not conflict with mirror edges, mirror frames or integrated shelving.

Basin Drain Relationship

Show the drain location relative to the faucet stream. Direct impact onto a drain cover or pop-up assembly may increase splash and should be reviewed during fixture coordination.

Front Basin Clearance

Maintain sufficient distance between the water-stream landing area and the front basin wall so splash is contained within the bowl during normal operation.

Rear Basin Clearance

Provide enough space between the mounting centerline and rear basin wall to prevent the water stream or sensor field from interacting adversely with the rear bowl surface.

Lateral Basin Alignment

The faucet centerline should generally coordinate with the intended basin washing zone. Offset installations should be reviewed carefully for water-stream capture and sensor performance.

User Hand Clearance

Provide adequate unobstructed space between the outlet and basin interior so users can wash comfortably without contacting the faucet, basin rim or drain assembly.

Splash-Control Envelope

Show the preferred basin area intended to contain the water stream and normal handwashing splash. Faucet height, projection, flow rate and basin geometry should be evaluated together.

Under-Counter Component Clearance

Confirm that the basin depth and mounting configuration leave sufficient space below the countertop for the faucet shank, hoses, mixing valve, control components and service access.

Final Coordinated Installation Envelope

The final drawing should combine faucet height, spout projection, basin geometry, sensor range, water-stream trajectory and concealed service requirements into one coordinated installation envelope.

Engineering note: Do not establish faucet installation height or basin clearance using a generic sink profile. Verify the actual basin rim elevation, bowl depth, drain location, faucet outlet position and sensor relationship before releasing countertop fabrication or plumbing coordination drawings.

Required Installation Height Drawing Views

Side Elevation

Show the faucet overall height, spout outlet height, countertop, basin profile, water-stream path and backsplash relationship.

Front Elevation

Show the faucet centerline, basin centerline, lateral clearances and relationship between the fixture and usable bowl width.

Basin Section

Show the basin rim, bowl depth, drain position and water-stream landing area relative to the faucet outlet.

Sensor Detection Diagram

Show the adjustable sensor zone relative to normal hand position, basin surfaces and water-stream location.

Countertop Plan View

Show the faucet centerline, basin opening, backsplash and horizontal spout-to-basin relationship.

Under-Counter Section

Show basin depth, faucet mounting stem, hoses and concealed control components to confirm adequate service clearance.

Faucet Height Coordination

Countertop Datum

Use the top finished surface of the countertop as the datum for all vertical faucet dimensions and installation-height references.

Fixture Overall Height

Confirm the overall faucet height against mirrors, backsplash features, shelves and wall-mounted accessories above the lavatory.

Outlet Elevation

Coordinate the water-outlet elevation with the actual basin rim and depth rather than selecting the faucet location independently.

User Working Zone

The vertical space between the outlet and basin should provide a natural working zone for handwashing without requiring contact with the faucet or bowl.

Sensor Working Zone

The infrared detection field should overlap the user working zone without remaining continuously activated by the basin surface.

Splash Performance

Higher outlet elevations can increase splash potential. Review the combined faucet and basin geometry during fixture selection and commissioning.

Basin Clearance Coordination

Spout Reach

The spout should extend sufficiently over the basin so water falls within the usable bowl rather than onto the rear rim or countertop.

Basin Rim

The basin rim should remain clear of the faucet outlet, user hand position and infrared detection path.

Bowl Depth

Deeper bowls generally provide greater splash containment, but under-counter clearance for controls and plumbing should also be considered.

Drain Position

Avoid aligning the water stream directly onto a raised drain fitting where doing so could redirect water toward the user or countertop.

Rear Bowl Wall

The rear bowl surface should not be so close to the faucet that it interferes with the sensor field or produces immediate splashback.

Front Bowl Wall

Maintain adequate distance between the stream landing point and front bowl wall to contain normal handwashing splash within the basin.

Sensor and Basin Relationship

Adjustable Detection Range

The Fontana technical documentation identifies an adjustable infrared detection zone of approximately 16–32 cm. Final sensor settings should be established after the faucet and basin are installed.

Reflective Basin Surfaces

Highly reflective polished metal, glass or glossy ceramic surfaces should be tested because reflected infrared energy can influence automatic sensor behavior.

False Activation Prevention

Adjust the sensor so the empty basin does not remain continuously within the detection field when no user is present.

Hand Detection

Confirm that hands approaching the normal wash area are detected quickly without requiring the user to reach excessively close to the basin or faucet.

Sensor-to-Stream Coordination

The sensor field should activate water while the user’s hands are positioned naturally below or near the outlet stream.

Commissioning Test

Perform repeated activation tests from different approach angles after the basin, countertop and surrounding finishes are fully installed.

Water-Stream & Splash-Control Coordination

Flow Rate

The current technical specification identifies approximately 1.2 GPM [4.54 L/min] at 60 PSI. Basin geometry should be selected to manage the resulting stream effectively.

Stream Landing Zone

Position the faucet so the stream contacts a relatively flat or gently curved section of the basin rather than a steep sidewall.

Drain Avoidance

Where practical, avoid direct impact on drain covers or raised waste fittings that may redirect the water stream.

Outlet Height

Do not increase the outlet-to-basin distance unnecessarily because greater fall height can increase water velocity at impact and splash.

Bowl Width

Ensure the basin provides adequate width around the stream landing zone for hand movement while maintaining splash containment.

Field Verification

Test the installed faucet at normal operating pressure and adjust available flow or sensor settings where required to achieve acceptable splash performance.

Recommended Height & Clearance Coordination Sequence

1. Confirm Faucet Model

Verify the final FS-1095GMG model and approved technical submittal before establishing installation geometry.

2. Confirm Basin Model

Obtain the exact basin dimensions, rim profile, depth, drain location and mounting arrangement.

3. Establish Countertop Datum

Use the finished countertop plane as the common vertical reference for faucet and basin coordination.

4. Position Faucet Centerline

Locate the faucet so the outlet projects into the desired basin washing zone.

5. Check Vertical Clearance

Verify the distance between the outlet and basin rim provides comfortable hand clearance without excessive stream drop.

6. Check Stream Landing Point

Confirm the projected stream lands inside the bowl and does not strike the rim or drain assembly unfavorably.

7. Check Sensor Relationship

Confirm the basin will not remain within the active infrared detection field during normal standby conditions.

8. Review Under-Counter Clearance

Verify that basin depth does not block the faucet mounting hardware, hoses or touchless control components.

9. Release Countertop Fabrication

Finalize the faucet mounting-hole location only after all above-deck and below-deck clearances have been coordinated.

10. Commission the Installed Fixture

Test sensor activation, water-stream alignment and splash containment after installation and make permitted adjustments as required.

Faucet Installation Height & Basin Clearance Notes

  • Finished countertop datum: Use the finished countertop surface as the vertical reference for faucet-height dimensions.
  • Actual basin required: Coordinate the faucet with the selected project basin rather than a generic sink profile.
  • Spout projection: The outlet should project into the usable basin area.
  • Vertical hand clearance: Provide sufficient space below the outlet for comfortable touchless handwashing.
  • Sensor range: The technical documentation identifies an adjustable detection range of approximately 16–32 cm.
  • Sensor interference: Test reflective basin surfaces during commissioning and adjust the sensor where required.
  • Stream landing: Avoid directing the water stream onto the basin rim, steep sidewall or raised drain fitting.
  • Splash control: Coordinate faucet height, flow rate, spout reach and basin depth as one system.
  • Backsplash clearance: Provide enough clearance for installation, cleaning and future maintenance.
  • Field commissioning: Verify sensor response and basin splash performance after the complete washroom finishes are installed.

Technical Performance Information

Detection Zone

The current FS-1095 technical specification identifies an adjustable infrared detection zone of approximately 16–32 cm.

Flow Rate

Technical documentation identifies approximately 1.2 GPM [4.54 L/min] at 60 PSI.

Water Connection

The faucet control system uses G1/2" inlet and outlet connections.

Temperature Mixing

The current technical specification identifies a below-deck manual mixing-valve arrangement.

Automatic Timeout

The electronic control system is specified with a factory-default 30-second timeout.

Response Performance

The FS-1095 technical documentation specifies automatic electronic opening in less than approximately one second.

Installation Height Drawing Component Identification

  • Finished countertop: Primary mounting and vertical-dimension reference plane.
  • Faucet body: Visible Gun Metal Gray touchless fixture above the countertop.
  • Spout outlet: Point from which the controlled water stream enters the basin.
  • Infrared sensor: Detects user hand presence and initiates automatic operation.
  • Sensor zone: Adjustable hand-detection region below and in front of the spout.
  • Basin rim: Upper edge or transition line defining the entrance to the bowl.
  • Basin interior: Usable handwashing and water-capture area.
  • Water-stream trajectory: Path from the faucet outlet to the basin landing point.
  • Stream landing point: Intended basin surface where the discharged water first contacts the bowl.
  • Basin drain: Waste outlet requiring coordination with the water-stream trajectory.
  • Backsplash: Rear architectural surface requiring clearance from the faucet body.
  • Mounting centerline: Primary horizontal location reference for faucet installation.
  • User working zone: Clear space between faucet outlet and basin used during normal handwashing.
  • Splash-control zone: Basin region intended to contain stream impact and handwashing splash.
  • Under-counter service zone: Space required for faucet mounting and concealed touchless components.

Professional Engineering and Accessibility References

Project verification: This faucet installation-height and basin-clearance resource is intended for architectural, plumbing, countertop and installation coordination and does not replace approved manufacturer installation instructions or project submittals. The architect, plumbing engineer, interior designer, countertop fabricator, millwork contractor and licensed installer should verify the finished countertop elevation, faucet mounting centerline, overall faucet height, spout outlet height, spout projection, basin rim elevation, bowl depth, drain location, water-stream landing point, sensor-detection relationship, backsplash clearance, under-counter service zone, accessibility requirements and locally adopted codes before fabrication or installation.