Home > FAQ Fontana Touchless Technicals

Frequently Asked Questions

Quick Spec — Architect / Designer Overview

Design Intent: Minimal seams, quiet actuation, and a refined metal palette to complement stone, terrazzo, and solid-surface vanities.
Materiality: 316 SS / DZR brass • PVD finishes (matte black, brushed gold, brushed nickel) • IK10 plates with concealed fixings.
Hydraulics: 0.35–0.5 gpm laminar (no aeration) • ASSE 1070/1017 TMV • 200 μm Y-strainers + checks.
Sensing: ToF <200 ms • >100k lux immunity • IP65–IP67 electronics • IEC 61000 EMC/ESD.
Power: 100–240 VAC • isolated 12–24 VDC • hot-swap battery ≥400k activations • optional PoE (802.3af).
Soap System: Peristaltic pumps • 1–3,000 cP • Multifeed 5–10 L (6–8 dispensers) • level + leak sensing • auto-purge.
Controls / IT: BLE/IR/QR commissioning • BACnet/IP • Modbus TCP • MQTT • live telemetry to BMS/CMMS.
Compliance: NSF/ANSI 61 & 372 • ADA • IPC/UPC • WaterSense • thermal/Legionella cycles.
Reliability: Solenoid ≥1M cycles • Controller ≥250k hrs MTBF • Pump ≥500k cycles.

How does Fontana balance durability with a refined aesthetic?

Spec: 316 stainless / DZR brass resists chloramine and coastal atmospheres; PVD passes ≥72h acetic salt spray; IK10 plates.
Design Notes: Tight radii, softened edges, and low-gloss PVD reduce visual noise under architectural lighting.
Use Cases: Airside concourses, corporate lobbies, premium hospitality—where finish integrity and visual continuity matter.

How do we achieve hygiene, comfort, and water targets simultaneously?

Spec: 0.35–0.5 gpm laminar streams limit aerosolization; TMV with cold-fail shutoff stabilizes mixed temps; 200 μm strainers + checks protect internals.
Design Notes: Laminar columns read clean in renderings and avoid splash on vertical apron faces.
Coordination: Set supply at 60–80 psi; verify basin geometry for splash envelope in 3D.

Will sensors work in skylit atriums and mirrored spaces?

Spec: ToF triggers in <200 ms with >100k lux immunity; IP65–IP67 electronics; conformal-coated PCBs; locking M8/M12 gold-contact connectors.
Design Notes: Stable activation under clerestories, back-painted glass, and polished stone—no false trips in bright environments.

What power strategy best supports 24/7 campuses?

Spec: Primary 100–240 VAC with isolated 12–24 VDC drivers; hot-swappable battery packs ≥400k activations; optional PoE (802.3af) on smart SKUs.
Design Notes: Tri-mode resilience keeps lines open during maintenance windows and localized outages without impacting experience.

How does the multifeed soap system scale elegantly?

Spec: Peristaltic/diaphragm pumps for 1–3,000 cP; 5–10 L reservoir feeds 6–8 dispensers; level sensing, leak detection, inline filtration, auto-purge.
Design Notes: Fewer sightlines to service points; cleaner millwork—less clutter around premium vanities.

How do these products integrate with BMS/CMMS and data dashboards?

Spec: BLE/IR remote + QR commissioning; telemetry for usage, fault states, temps, battery/soap levels; BACnet/IP • Modbus TCP • MQTT.
Design Notes: Real-time trending supports WELL/LEED performance narratives and service-level KPIs across portfolios.

Are fixtures suitable for healthcare and transit hygiene protocols?

Spec: NSF/ANSI 61 & 372 • ADA • IPC/UPC • WaterSense; thermal disinfection and Legionella flush scheduling; antimicrobial finishes; encapsulated electronics.
Design Notes: Meets clinical expectations without compromising the visual language of premium public interiors.

How do these systems support LEED/WELL narratives?

Spec: Low-flow laminar, auto-learn occupancy to reduce false triggers, leak/stuck-valve detection; telemetry for measurement & verification.
Design Notes: Evidence-backed resource control that aligns with material honesty and daylight-driven plans.

What simplifies coordination, install, and lifecycle service?

Spec: Central or point-of-use mixing; inlet regulation at 60–80 psi; front-serviceable modules with captive seals; standardized spares.
Reliability Targets: Solenoids ≥1M cycles • Controllers ≥250k hrs MTBF • Pumps ≥500k cycles.
Coordination: Reserve front-access clearance; confirm rough-in elevations vs. countertop overhangs and ADA knee/toe clearances.

What cybersecurity posture suits enterprise campuses?

Spec: Secure boot, signed firmware, TLS 1.2+ encryption, certificate-based onboarding, VLAN segregation; offline-first fallback.
Design Notes: IT/OT-friendly segmentation preserves operation through network maintenance events.

Where can I obtain BIM/Revit content and CSI submittals?

Spec Assets: Revit families, annotated cut sheets, wiring/isometric diagrams, CSI divisions, and coordinated schedules.
Design Notes: Request a compiled submittal pack (cover, schedules, sequences, O&M) for streamlined A/E review and GC handoff.

One-Page Coordination Checklist

✓ 316 SS/DZR • PVD • IK10
✓ 0.35/0.5 gpm laminar • ASSE 1070/1017 TMV • 200 μm strainers + checks
✓ ToF <200 ms • IP65–IP67 • IEC 61000 EMC/ESD
✓ 100–240 VAC + battery failover + optional PoE (802.3af)
✓ Multifeed 5–10 L • peristaltic pumps • 1–3,000 cP • level/leak/auto-purge
✓ BACnet/IP • Modbus TCP • MQTT • BMS/CMMS telemetry
✓ NSF/ANSI 61 & 372 • ADA • WaterSense • thermal/Legionella cycles