Home > FontanaTouchless Seira Model Standarad Countertop Installation Drawing

Fontana Automatic Soap Dispensers™ | Architectural and Engineering Resource

Fontana FS9836DP Deck-Mounted Automatic Soap Dispenser: Countertop Installation Drawing

This countertop installation drawing resource supports architects, plumbing engineers, interior designers, contractors, millwork fabricators, installers and facility managers coordinating the Fontana FS9836DP deck-mounted automatic soap dispenser within commercial washrooms. The drawing explains how the dispenser passes through the countertop, how its mounting components are assembled and how the concealed soap and electrical components should be arranged below the counter.

Fontana FS9836DP Deck-Mounted Automatic Soap Dispenser

The Fontana FS9836DP is a commercial automatic soap dispenser designed for installation through a prepared countertop opening. Its above-counter spout provides touch-free soap delivery while the threaded mounting shank, soap tube, pump, reservoir and power components remain concealed inside the vanity or millwork cabinet.

  • Model: FS9836DP
  • Product type: Automatic soap dispenser
  • Installation: Deck mounted
  • Mounting location: Countertop or lavatory deck
  • Operation: Touch-free sensor activation
  • Soap supply: Concealed under-counter reservoir
  • Service access: From below the countertop
  • Application: Commercial and institutional washrooms

Countertop Installation Drawing Scope

The countertop installation drawing should include a side-section view through the dispenser, mounting deck and under-counter assembly. Dimensions should be referenced from the finished countertop surface, centerline of the mounting opening and soap outlet. Metric and imperial measurements should be shown wherever verified product dimensions are available.

Countertop Section View

Shows the dispenser installed through the countertop in cross-section. The drawing should identify the above-counter spout, mounting base, gasket, countertop, threaded shank, washer, retaining nut, soap tube and electrical cable. This provides installers with a complete view of how the product is secured to the deck.

Countertop Opening

Identifies the required mounting-hole diameter and its permitted tolerance. The hole should be centered at the approved installation location and drilled perpendicular to the finished surface. Final opening dimensions must be verified from the approved FS9836DP specification or installation documentation.

Maximum Counter Thickness

Shows the permitted countertop thickness that can be accommodated by the dispenser’s threaded mounting shank. The drawing should allow enough exposed thread below the deck for the washer and retaining nut to engage securely without interfering with tubing or electrical connections.

Mounting Base and Gasket

Illustrates the relationship between the dispenser base, sealing gasket and finished countertop. The gasket should sit evenly beneath the base to help stabilize the dispenser and limit water intrusion through the mounting opening.

Washer and Retaining Nut

Shows the washer and mounting nut beneath the countertop. The washer should remain flat against the underside of the deck while the nut is tightened sufficiently to secure the dispenser without damaging stone, quartz, solid-surface material or laminated millwork.

Spout Reach and Outlet Position

Identifies the horizontal projection from the dispenser centerline or mounting base to the soap outlet. The outlet should be positioned over the usable capture area of the lavatory so dispensed soap falls inside the basin rather than onto the countertop or backsplash.

Sensor Location and Activation Area

Locates the infrared sensor and illustrates the intended hand-detection area beneath the soap outlet. The sensor path should remain clear of the basin rim, raised backsplash, reflective trim and accessories that could obstruct detection or cause unintended activation.

Under-Counter Soap Tube

Shows the soap tube extending downward from the dispenser shank toward the pump and reservoir. Tubing should follow a smooth route without sharp bends, crushing, excessive tension or contact with cabinet hardware that could restrict soap movement.

Electrical Cable Routing

Identifies the concealed cable path between the sensor dispenser, control module, pump and approved power source. Wiring should be kept clear of wet areas, sharp edges, moving cabinet components and routine soap-reservoir removal paths.

Soap Reservoir Position

Shows the reservoir below the countertop and within practical reach of maintenance personnel. The container should remain upright, accessible for refilling and positioned so its tube connection is not kinked or stretched.

Counter Edge Clearance

Defines the recommended space between the dispenser mounting centerline and the front or rear counter edge. Adequate clearance is required to accommodate the mounting nut, hand tools, soap tubing and nearby lavatory components below the deck.

Backsplash Clearance

Shows the horizontal separation between the rear of the dispenser and the backsplash or finished wall. This space should permit cleaning, installation tool access and removal of the dispenser body when maintenance is required.

Faucet-to-Dispenser Spacing

Coordinates the soap dispenser with the adjacent faucet. Sufficient spacing should be maintained between mounting holes, escutcheons, threaded shanks, supply hoses, sensor cables and concealed components below the countertop.

Service Clearance

Defines the unobstructed area required below the counter for tightening the mounting hardware, disconnecting the soap tube, servicing the pump, accessing the controller and removing the reservoir for cleaning or refilling.

Finished Installation Detail

Shows the complete installed configuration with the spout above the counter, the outlet aligned over the lavatory and the reservoir, pump, controller, tubing and power connections organized below the deck.

Engineering note: Do not use estimated mounting-hole, counter-thickness, projection or clearance dimensions in construction documents. Confirm all final measurements from the approved FontanaShowers specification sheet, installation instructions or project submittal before drilling the countertop.

Recommended Countertop Installation Sequence

1. Confirm the Location

Coordinate the dispenser centerline with the lavatory, faucet, backsplash and under-counter cabinet components. Verify that the soap outlet will discharge into the basin’s usable area.

2. Verify the Countertop

Confirm the deck material, thickness and structural condition. The surface should be rigid, level and suitable for drilling without cracking, delamination or unsupported movement.

3. Prepare the Opening

Mark the approved centerline and create the mounting opening using the correct tool for the countertop material. Remove debris and protect the finished surface from chipping or scratching.

4. Install the Gasket

Place the supplied gasket beneath the dispenser base. Ensure it lies flat and remains centered around the mounting opening before inserting the threaded shank.

5. Insert the Dispenser

Feed the threaded shank, soap tube and sensor cable through the countertop opening. Orient the soap outlet toward the center of the lavatory before securing the assembly.

6. Secure the Mounting Hardware

Install the underside washer and retaining nut. Hold the dispenser in its correct orientation while tightening the nut evenly. Do not over-tighten against stone or brittle countertop materials.

7. Connect the Soap Tube

Route the soap tube to the pump or reservoir connection. Keep the path smooth, shorten only where permitted and verify that all connections are fully seated.

8. Connect the Control Components

Connect the sensor, pump, controller and approved power source according to the product instructions. Keep electrical connections dry, supported and accessible for future servicing.

9. Install the Soap Reservoir

Position the reservoir upright below the dispenser. Provide enough clearance to remove its cap, disconnect the tube and withdraw the container without disturbing plumbing or cabinet hardware.

10. Prime and Test

Fill the reservoir with compatible soap, prime the pump and test several activation cycles. Confirm consistent dispensing, accurate sensor response and correct soap delivery into the basin.

Architectural and MEP Coordination Considerations

Lavatory Alignment

Align the soap outlet with the basin’s usable capture area to reduce soap residue on the counter, backsplash and floor.

Countertop Fabrication

Include the verified dispenser opening in countertop shop drawings and coordinate it with faucet holes, sink clips, seams and structural supports.

Undermount Sink Clearance

Check for conflicts between the dispenser shank and the sink rim, mounting rails, clips, adhesive supports or reinforcing brackets beneath the counter.

Accessible Reach

Coordinate the dispenser location and sensor activation area with the accessible lavatory approach and applicable reach-range requirements.

Power Coordination

Confirm the specified power arrangement and coordinate the controller, transformer, receptacle or battery compartment with the electrical drawings.

Service Access

Preserve access to the mounting nut, soap tube, pump, controller, reservoir and power components without removing permanent millwork.

Countertop Installation Drawing Requirements

  • Front elevation: Show the dispenser centered in relation to the lavatory and indicate the soap outlet, sensor position and finished countertop.
  • Side section: Show the spout, countertop, gasket, threaded shank, washer, retaining nut, tube, cable and under-counter reservoir.
  • Top plan: Show the mounting centerline, base footprint, outlet direction, faucet spacing and relationship to the lavatory opening.
  • Mounting-hole detail: Provide the verified hole diameter, tolerance and countertop-thickness requirement.
  • Clearance detail: Identify counter-edge, backsplash, basin, faucet and under-counter service clearances.
  • Dimension format: Provide verified measurements in millimeters and inches with consistent dimension arrows, centerlines and leader notes.
  • Component identification: Label the dispenser body, sensor, soap outlet, gasket, shank, washer, retaining nut, tube, pump, reservoir, controller and power source.
  • Drawing notes: Include installation warnings, verification requirements, scale notation, model number and revision information.

Professional Engineering and Accessibility References

Project verification: This countertop installation drawing is a coordination resource and does not replace an approved project submittal. The architect, engineer, countertop fabricator and licensed installer should verify final product dimensions, mounting-hole diameter, deck thickness, clearances, power requirements, accessibility criteria and locally adopted codes before fabrication or installation.