Fontana Solo Rose Gold Commercial Automatic Touchless Sensor Faucet
Solo Rose Gold Commercial Automatic Touchless Sensor Faucet
 
Alternative Views:


List Price $947.04
Sale Price: $794.26
Savings: $152.78

Sale Price: $794.26







Free Shipping
Availability: Usually Ships in 5 to 10 Business Days
Product Code:
FS-987RG


Hot & Cold Option:


Qty:  
Description Technical Specs Extended Information
 

Fontana Solo Rose Gold Commercial Automatic Touchless Sensor Faucet

Advanced infrared sensor technology delivers instant, touchless activation with precise detection, optimizing hygiene and water efficiency in high-traffic commercial restroom environments. Commercial-Grade Smart Faucet; Built for professional facilities with intelligent sensor control, water-saving flow rates, vandal-resistant aerators, ADA compliance, and reliable automatic shut-off. Reduces the transfer of germs by preventing cross-contamination and re-contamination of germs and bacteria by not touching the faucets or handles. Cut down on water usage by minimizing waste of water by eliminating unnecessary or unattended water flow. Interference check identifies conflicts with backsplashes, supports, and sink geometry. Interference check identifies conflicts with backsplashes, supports, and sink geometry.

Fontana Solo Commercial Rose Gold Automatic Touchless Sensor Faucet

Infrared Trigger Precision, Solenoid Cycle Integrity & Commercial Water-Control Engineering

Engineered for commercial washrooms, this rose gold touchless faucet integrates infrared sensing with automatic water control for reliable, high-cycle hands-free operation.

How can sensor hysteresis improve activation and shutoff stability?
A controlled difference between detection and release thresholds helps prevent rapid valve cycling when hands move near the edge of the sensing field. During commissioning, the completed basin environment should be tested to ensure stable activation without oscillation caused by marginal infrared reflections.
Why is solenoid sealing integrity critical after thousands of operating cycles?
The solenoid repeatedly isolates pressurized water after every handwashing event. Its sealing interface must remain free of sediment and dimensional wear to achieve positive closure; even small particles trapped at the valve seat can produce continuous seepage or delayed automatic shutoff.
How can simultaneous fixture demand affect sensor-faucet hydraulic performance?
When multiple fixtures operate together, increased branch-line velocity creates additional friction loss and reduces dynamic pressure at individual outlets. Commissioning under representative peak demand confirms that the faucet maintains stable discharge rather than relying solely on higher static pressure measurements.
What diagnostic sequence should be used if activation occurs but flow is weak?
Technicians should first verify that isolation stops are fully open, then inspect inlet strainers for debris and confirm adequate dynamic supply pressure. If these conditions are satisfactory, the solenoid waterway and outlet should be checked for restriction before the electronic sensor assembly is serviced.
  • Brand Name: FontanaShowers
  • Model Number: FS-987RG
  • Diameter of inlet pipe: DN15
  • Diameter of outlet pipe: DN15
  • Water Pressure: 0.05Mpa - 0.7Mpa
  • Power: DC.6V
  • Power Consumption: 0.5MW
  • Detection Zone: Factory set 25cm/10" (based on standard inductive board)
  • Ambient Temperature: 1 - 45 °C / 33.8 -113 °F
  • Degree of protection by enclosure: 1P56
  • Battery: 4 x 'AA' size cells
  • Operational water pressure range: 0.05 - 0.6MPa
  • US standard water supply pipe size: DN15 (G1/2")
  • Ambient temperature range: 0.1 - 45ºC
  • Sensing distance: 9.84" (25cm)
  • Time delay: 0.5 seconds
  • Operation duration: Power will automatically cut off after continuous use for 60 seconds
  • Manufacturer Warranty: 10-Years
  • Color: Chrome

Features

  1. Infrared sensor operated, touch-free operation
  2. Advanced energy-saving design for long-lasting battery life
  3. Waterproof sensor
  4. Battery low LED light indicator
  5. Sensing distance adjusted automatically
  6. Long life durable body
  7. Advanced circuit design saves electricity and water

Sensor Tap Advantage

  1. Conserves water
  2. Saves energy during the water heating process
  3. Hygienic, no-touch activation
  4. Easy installation
  5. Durable, solid all-brass construction
  6. Built-in filter
  7. ADA compliant Ideal for use by disabled people
  8. Vandal resistant
  9. Waterproof Components
automatic-faucet-diagram automatic-faucet-rohos automatic-faucet-ceimages
Fontana SoloSupreme™ Line rose gold

Average Rating: Average Rating: 4.5 of 5 4.5 of 5 Total Reviews: 8 Write a review »

  5 of 5 people found the following review helpful:
 
4 of 5 Beauty Survives Duty Saturday, August 15, 2026
Reviewer: Phillip Dawson from New Orleans, LA  
Solo proves that a rose-gold commercial faucet does not have to depend entirely on appearance. Fontana's specification sheet lists adjustable 16�32 cm sensing, opening in under one second, closing in under two seconds, AC 220�240V or four-AA battery operation, G1/2 connections, 0.1�0.7 MPa water pressure, and an approximately 100,000-cycle battery lifespan. Those are useful operating benchmarks beneath a finish normally associated with decorative residential fittings. Rose gold still requires disciplined finish coordination and non-abrasive maintenance, particularly where surrounding drains and accessories come from different manufacturers. From a facilities perspective, I would standardize battery replacement and sensor checks across all installed units. That approach lets Solo retain its upscale character without becoming a special-case fixture for the maintenance department.

Was this review helpful to you?

  1 of 1 people found the following review helpful:
 
4 of 5 Design Team Won This One Wednesday, July 29, 2026
Reviewer: Christine Maddox from Newport Beach, CA  
Our operations group voted for something more conventional, while the designer kept pushing the rose gold Solo. She won, and after seeing the completed hotel washroom I understand why. It has a much more distinctive presence than the standard sensor faucets we use elsewhere. Automatic operation has been consistent and guests haven't struggled with it. We do baby the finish a little during cleaning, but that's been manageable. For a premium public-facing space, the visual improvement was worth it.

Was this review helpful to you?

  1 of 1 people found the following review helpful:
 
4 of 5 System Capacity Expanded Tuesday, July 7, 2026
Reviewer: Connor Hayes, Facility Manager from Spokane, WA  
Following installation throughout a convention center renovation, restroom throughput improved substantially without increasing maintenance workload. Fast sensor recognition, dependable shutoff logic, and consistent electronic operation have supported higher daily usage while preserving long-term equipment reliability.

Was this review helpful to you?

  1 of 1 people found the following review helpful:
 
4 of 5 Commissioning Simplified Sunday, July 5, 2026
Reviewer: Harrison Cole, Engineer from Lexington, KY  
This rose gold commercial sensor faucet completed startup verification without electrical or hydraulic adjustments. Engineering acceptance was completed on the first inspection, reducing project closeout time.

Was this review helpful to you?

  3 of 3 people found the following review helpful:
 
5 of 5 Reduced Flow Complaints Thursday, May 14, 2026
Reviewer: Elliot Whitmore, Infrastructure Advisor from Sarasota, FL  
We upgraded several hospitality restroom suites between 2022 and 2025 after earlier rose-gold touchless faucets repeatedly developed inconsistent stream behavior, unstable infrared activation, and delayed shutoff timing during continuous guest usage, and by 2026 this faucet has maintained considerably steadier operational consistency than previous decorative sensor fixtures installed in comparable luxury environments. Earlier systems frequently struggled with reflective sink interference and fluctuating inlet-pressure conditions that triggered repeated recalibration requests, whereas this faucet maintained smoother activation timing with more dependable stream regulation throughout repeated operation cycles. Housekeeping teams also noted that the rose-gold finish concealed light maintenance spotting more effectively than polished decorative fixtures previously installed in the same properties. One reflective countertop setup required additional sensitivity refinements during installation, but once optimized the infrared responsiveness and valve reliability remained highly dependable overall.

Was this review helpful to you?

View All Customer Reviews



ToF Sensor Faucet Vs IR Sensory
Commercial Touchless Bathroom Sink Faucets
Best Quality Touchless Faucet
Best Quality Motion Sensor Faucet
Touchless Faucets > Touchless Sensor Faucets
Touchless Faucets
Touchless Faucets > Countertop Touchless Faucets
Touchless Faucets > Touchless Bathroom Faucets