Fontana MotionSense Chrome Touchless Faucet FAQ
Sensor Calibration, Supply Flushing & Ceramic Mixing Commissioning
This chrome deck-mounted touchless basin faucet combines infrared hands-free activation,
single-hole installation, hot-and-cold mixing, and a ceramic valve core.
How should the sensor field be tested after the faucet is installed?
Test hand entry from several approach angles and confirm rapid activation without detecting the basin surface, backsplash, mirror edge, or nearby reflective accessories. Complete final sensor validation only after the finished basin area is installed.
What flushing procedure is required before connecting the faucet controls?
Flush the hot and cold supply branches independently until construction debris is cleared, verify the correct inlet orientation, and prevent sediment from entering the ceramic mixing valve or electronically controlled waterway.
How should the hot-and-cold mixing range be commissioned?
Open both isolation valves gradually, operate the temperature adjustment through its complete range, verify stable mixed-water delivery, and inspect the ceramic valve housing and supply connections for leakage.
What should be checked during the final automatic shutoff test?
Trigger the faucet repeatedly, remove the target from the sensor field, and confirm that flow terminates consistently without delayed closure, solenoid chatter, residual dripping, false reactivation, or pressure-related cycling.