Home > Installation Instruction for Clares Commercial Oil Rubbed Bronze Automatic Touchless Bathroom Faucets

How to install Clares Commercial Oil Rubbed Bronze Automatic Sensor Faucets | FS-AORB


Visit Product Page
Easy step by steps Installation Instructions for Commercial Automatic Sensor Faucet

  • Before you begin, please read the installation instructions below. Observe all local building and safety codes.
  • Unpack and inspect the product for any shipping damages. If you find damages, do not install.
  • Please note all products must be installed by a professional and certified plumber otherwise warranty might be voided.
sensor Clares Commercial Oil Rubbed Bronze Automatic Sensor Faucets

Sensor Faucet Installations Instructions


Size:

Deck Mount Installation



Battery (DC 6V) Only Control Box
Step 1:Step 2: (Hot & Cold Connection)

sensor



Battery (DC 6V) & AC 220V Control Box
Step 3:Step 4:


Step 5: Flush Debris from waterpipesStep 6: Hot & Cold Regulator


Step 7:Step 8: (Correct way for Hose)



1. Screw the hose into the corresponding screw-hole of the faucet body. Fix the o-ring into the bottom groove of the faucet body.

2. Insert hose, threaded pipe and data cable through the drilled hole of the countertop. Put rubber washer and metal washer onto the threaded pipe, screwing in mounting nut. Adjust the faucet body correctly and tighten the mounting nut with screws.

3. Install the control box to the wall and fix it with screws.

4. Add the rubber washer and screw supply elbow to the control box.

5. Add rubber washers and connect water lines to the hot and cold inlets of the supply elbow. Then connect the hose to the water outlet and insert data cable into the control box and plugin.

6. Make Connections to water supplies. Turn on hot and cold water supplies and flush water lines into a container for one minute. Important: This flushes away any debris that could cause damage to internal parts.

7. Connect waterlines to angle stops. Turn on the angle stops and check for leaks (DO NOT TURN FAUCET ON).

8. Turn the faucet on for 1 minute to flush any debris.


Flexible Connecting Hose

Care must be taken when connecting the flexible connection hose from the power supply box to the spout to ensure it does not bend sharply and kink or twist.
See above for recommended ways to fit the flexible connecting hose.

Important: Failure to follow these guidelines may result in poor performance and damage to the flexible connection hose.



Control Box Installation Instructions

Step 1:Step 2:
control box
Step 3:Step 4:
5" size
Step 5:Step 6:
Inserting Batteries
Your infrared spout is supplied with a back up battery pack (batteries not included). In the event of a power failure the batteries will override the mains power supply to ensure the spout continues to function.


Before fitting the power supply box into position on the wall/floor, batteries (not included) will need to be fitted.

1. Remove Power Supply Box Cover
Remove all four screws in each corner of the power supply box and remove the cover.

2. Remove Battery Box
Remove the battery case from the power supply box and remove the screw in the center of the case.

3. Insert Batteries
Insert 4 x AA batteries (not included) into the battery box ensuring they are inserted the correct way.
Note: Only use 1.5V AA (LR6) Alkaline batteries (preferably => 2000mAh for good battery life).

4. Replace Battery Box
Replace the battery case cover. Replace and tighten the screw. Insert the battery case back into the power supply box.

5. Replace Power Supply Cover
Replace the power supply cover and tighten all 4 screws ensuring they are all fully tightened.


Installation - Electrical Connections


1. Position Power Supply Box
Position the power supply box onto the wall surface below the sink/work surface where it is easily accessible.

Note: Ensure that the power supply box is fitted the correct way up (see opposite) and that the flexible hose will reach from the underside of the spout to the power supply box.

Using suitable fixings for the wall type secure the power supply box to the wall.

2. Connect Power Supply Cable
Before starting any electrical work ensure the power supply is isolated. Wire the electrical power cable into a switched fused spur off the ring main. The blue wire should be wired to the neutral connection and the brown wire should be connected to the live connection.

Important: The power supply box must be permanently connected to the fixed wiring of the mains supply using the factory supplied power cable.

3. Plug In Power Cable
Plug the power cable into the power supply box.

4. Connect The Sensor Cable
Plug the sensor cable from the spout into the power supply box to activate the infrared senor.


Installation - Water Connections

Connecting Water Supply
A blended water supply is required to the inlet of the power supply box. Before connecting the water supply to the power supply box flush through the pipework to ensure removal of debris. Once flushed through turn off the mains water supply and close any isolating valves.

Inlet Connection
The inlet connection on the power supply box is a 1/2” BSP male threaded connection. Connect a 1/2” BSP female connector to the inlet connection ensuring a suitable sealing washer is used to create a water tight connection.

Outlet Connection
The outlet connection is a standard 1/2” BSP male threaded connection. Connect the flexi hose (supplied) to the outlet connection, ensuring it is tightened fully.

























Sensor Activated Faucet Special Features

  • Durable Vandal-Resistant Brass Body; Ideal for Residential as well as commercial high use applications
  • Intelligent: with its micro-computer controlling its action, the faucet will self adjust its best detection zone as per the color and shape of lavatory
  • Flashing light indicator; a diagnostic indicators for power up, low battery, and solenoid function.
  • Meaning of the codes are described in the installation instructions.
  • Convenient to maintain; with built-in strainer to prevent sundries from entering the solenoid valve and the strainer is easy to clean
  • Faucet can be mount to any sink surface.
  • ADA Compliant.
  • Batteries life 8,000 cycles per month and with enough water pressure is approx 5 year service life of the batteries.
  • Adjustable sensing range; while the factory range is set about 4"to 5"from the sensor, it can be adjusted.


Clares Automatic Faucet Specifications

Diameter of inlet pipeDN15
Diameter of outlet pipeDN15
Faucet height12.59" (320mm)
Spout length3.14" (80mm)
Spout height10.23" (260mm)
Water Pressure0.05Mpa - 0.7Mpa
Power and VoltageDC.6V / AC.220V - 50/60Hz
Power Consumption0.5MW
Detection ZoneFactory set 25cm/10" (based on standard inductive board)
Ambient Temperature1 - 45 °C / 33.8 -113 °F
Degree of protection by enclosure1P56
Battery4 x 'AA' size cells
Operational water pressure range0.05 - 0.6MPa
Water supply pipe size

BathSelect Ancient Round Antique Rainfall Wall ShoweBathSelect Ancient Round Antique Rainfall Wall Shower Head Installation Instructions Head Installation Instructions